In modern construction practices and energy-efficient renovations, building envelopes are becoming increasingly airtight. While this makes sense from an energy efficiency standpoint, it often leads to major problems without systematic planning: moisture damage and mold growth are inevitable. Nevertheless, many developers, architects, and planners ignore the need for a formal ventilation plan—a risk that can prove costly.
Translated with DeepL.com (free version)
The legal and regulatory obligation
According to DIN 1946-6, a ventilation plan must be prepared for every new building as well as for renovations in which more than one-third of the windows are replaced, more than one-third of the facade is insulated, or more than one-third of the roof is insulated.
Its purpose is to determine whether the air exchange through leaks in the building envelope (infiltration) is sufficient to ensure moisture protection. If this is not the case, ventilation measures must be defined.
The levels of ventilation according to the standard
A professional design takes into account four stages of ventilation:
- A professional design takes into account four stages of ventilation:
- A professional design takes into account four stages of ventilation:
- Nominal ventilation (NL): Standard operation when occupants are present.
- Intensive ventilation (IL): Reducing peak loads (e.g., when cooking or showering).
Risks of non-compliance
If a ventilation plan is not implemented, two main risks arise:
Building Structure & Hygiene:
Without a user-independent minimum air exchange rate, the relative humidity in the rooms increases. This inevitably leads to mold growth at geometric and structural thermal bridges.
A liability pitfall for planners:
DIN 1946-6 is considered a recognized standard of engineering practice. If the design is lacking and damage occurs, the burden of proof lies with the designer or developer. Today, a reference to “tenants’ ventilation habits” is often no longer sufficient from a legal standpoint if the structural requirements for moisture protection have not been demonstrated.
For more information on this topic, click here: Ventilation design according to DIN 1946-6